NORRIS PAINT & VARNISH CO -- PAINT, OIL, FLAT INTERIOR -- 8010-00-584-3136
=====================  Product Identification  =====================

Product ID:PAINT, OIL, FLAT INTERIOR
MSDS Date:01/01/1985
FSC:8010
NIIN:00-584-3136
MSDS Number: BFGMG
=== Responsible Party ===
Company Name:NORRIS PAINT & VARNISH CO
Address:1675 COMMERCIAL ST NE
Box:2023
City:SALEM
State:OR
ZIP:97308
Country:US
CAGE:GO781
=== Contractor Identification ===
Company Name:NORRIS PAINT & VARNISH CO
Box:2023
CAGE:GO781
Company Name:NORRIS PAINT CO., DIV WHITTAKER COATINGS
Address:1675 COMMERCIAL ST NE
Box:2023
City:SALEM
State:OR
ZIP:97308
Country:US
Phone:503-364-2277
CAGE:33148

=============  Composition/Information on Ingredients  =============

Ingred Name:PIGMENTS
Fraction by Wt: 56.0%

Ingred Name:VEHICLE
Fraction by Wt: 13.0%

Ingred Name:SOLVENTS
Fraction by Wt: 28.8%
ACGIH TLV:500PPM

Ingred Name:ADDITIVES
Fraction by Wt: 2.0%

=====================  Hazards Identification  =====================

Effects of Overexposure:EYE/THROAT/SKIN/LUNG IRRIT

=======================  First Aid Measures  =======================

First Aid:WASH SKIN THOROUGHLY, FLUSH EYES W/WATER, REMOVE TO FRESH
    AIR, REMOVE CONTAM CLOTHING. GIVE ARTIF RESP IF NEEDED, CALL MD. DO
    NOT INDUCE VOMIT IF SWALLOWED.

=====================  Fire Fighting Measures  =====================

Flash Point:106F, 41.1C TOC
Extinguishing Media:FOAM, DRY CHEM, FOG, CARBON DIOXIDE
Fire Fighting Procedures:USE WATER SPRAY TO COOL CNTNRS. WEAR RESP.
Unusual Fire/Explosion Hazard:AVOID FIRE, HEAT, SPARKS, IGNIT SOURCES,
    STG IN DIRECT SUNLIGHT. TOXIC FUMES.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENT AREA MECH, KEEP FROM FLAME, FIRE, SPARKS,
    IGNIT SOURCES. DO NOT BREATHE VAPORS. CLEAN UP W/ABSORBENT MATL.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CNTNRS CLOSED, UPRIGHT, AWAY FROM
    FIRE, FLAME, SPARKS, IGNIT SOURCES, DIRECT SUNLIGHT.
Other Precautions:CNTNRS HAZ WHEN EMPTIED

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:SELF-CNTND BRTHNG APPARATUS
Ventilation:LOCAL EXHST
Protective Gloves:GLOVES
Eye Protection:GOGGLES/GLASSES
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:310F,154.4C
Vapor Pres:045
Vapor Density:6.0
Spec Gravity:1.4160
Solubility in Water:NONE
Appearance and Odor:VISCOUS OPAQUE LIQ, PETROLEUM ODOR
Percent Volatiles by Volume:28.8

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS

====================  Disposal Considerations  ====================

Waste Disposal Methods:ALLOW VOLATILE PORTION TO EVAPORATE, BURN
    REMAINDER. CONTAM ABSORBENT TO LANDFILL.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.