E. I. DUPONT DE NEMOURS AND COMPANY -- FREON 500 REFRIGERANT -- 6830-01-137-7971
=====================  Product Identification  =====================

Product ID:FREON 500 REFRIGERANT
MSDS Date:06/10/1991
FSC:6830
NIIN:01-137-7971
MSDS Number: BGNNJ
=== Responsible Party ===
Company Name:E. I. DUPONT DE NEMOURS AND COMPANY
Address:FREON PRODUCTS DIVISION
City:WILMINGTON
State:DE
ZIP:19898
Info Phone Num:302-774-2421/800-441-9450
Emergency Phone Num:800-441-3637/800-424-9300(CHEMTREC)
Preparer's Name:W.J. BROCK, 302-999-5072
CAGE:73925
=== Contractor Identification ===
Company Name:DU PONT E I  DE NEMOURS AND CO INC   PETROCHEMICALS DEPT
Address:1251 BRANDYWINE BLDG
Box:City:WILMINGTON
State:DE
ZIP:19898
Phone:302-773-5676
CAGE:73925

=============  Composition/Information on Ingredients  =============

Ingred Name:DICHLORODIFLUOROMETHANE  (SARA III) (FREON 12)
CAS:75-71-8
RTECS #:PA8200000
Fraction by Wt: 73.8%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9394
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ozone Depleting Chemical:1

Ingred Name:DIFLUOROETHANE (FC-152A)
CAS:75-37-6
RTECS #:KI1410000
Fraction by Wt: 26.2%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHAL:HI VAP CONC HARMFUL,MAY CAUSE
    HEART IRREG,UNCONSC,DEATH,CNS DEPRESS.VAP REDUCES OXY AVAILABLE FOR
    BREATH & IS HEAVIER THAN AIR.LIQ CONTACT CAN CAUSE
    FROSTBITE.SKIN:FROSTBITE,MILD SKIN IRRIT W/DI SCOMFORT.EYE:IRRIT
    W/DISCOMFORT.>20% EXPO TEMP LUNG IRRIT & ALTERATION OF HEART
    ELECTRICAL ACTIVITY W/IRREG PULSE,(SUPP)
Explanation of Carcinogenicity:PER MSDS:NONE OF COMPONENTS PRESENT IN
    MATL @CONC =/>0.1% ARE LISTED BY IARC/NTP/OSHA/ACGIH AS A
    CARCINOGEN.
Effects of Overexposure:HEART IRREG,UNCONSC,DEATH.FROSTBITE.MILD SKIN
    IRRIT W/DISCOMFORT.EYE TEARING,BLURRING OF
    VISION.INHAL:NAUSEA,HEADACHE,WEAKNESS,TEMP NERVOUS SYSTEM
    DEPRESSION W/ANESTHETIC EFFECTS SUCH AS DIZZINESS,HEA
    DACHE,CONFUSION,INCOORDINATION,LOSS OF CONS.TEMP LUNG
    IRRIT-COUGH,DISCOMFORT,DIFFICULTY BREATHING,SHORTNESS OF BREATH.
Medical Cond Aggravated by Exposure:INDIVIDUALS W/PRE-EXISTING DISEASES
    OF CENTRAL NERVOUS SYS,CARDIOVASCULARSYS,LUNGS OR KIDNEYS MAY HAVE
    INCREASED SUSCEPTIBILITY TO TOXICITY OF EXCESSIVE EXPOSURES.

=======================  First Aid Measures  =======================

First Aid:INHAL:IMMED REMOVE TO FRESH AIR.KEEP PERSON CALM.NOT BREATH
    GIVE ART RESP.BREATH DIFFICULT GIVE OXY.CALL PHYSICIAN.SKIN:FLUSH
    W/WATER FOR 15MINS.TREAT FOR FROSTBITE BY GENTLY WARMING AFFECTED
    AREA.IRR IT PRESENT GET MED ATTN.EYE:IMMED FLUSHW/PLENTY OF WTER
    FOR 15MINS.CALL PHYSICIAN.INGEST:NOT CONSIDERED POTENTIAL ROUTE OF
    EXPOSURE.PHYSICIAN:BECAUSE OF POSSIBLE DISTURBANCES OF CARDIAC
    RHYTHM (SUPP)

=====================  Fire Fighting Measures  =====================

Flash Point:WILL NOT BURN
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS IS REQUIRED
    IF CYLINDERS RUPTURE OR RELEASE UNDER FIRE CONDITIONS.USE WATER
    SPRAY/FOG TO COOL CNTNR.
Unusual Fire/Explosion Hazard:CYL ARE EQUIPPPED W/TEMP/PRESSURE RELIEF
    DEVICES BUT MAY STILL RUPTURE UNDER FIRE CONDITIONS.DECOMPOSITION
    MAY OCCUR.

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE APPROPRIATE PPE DURING CLEANUP.VENTI AREA
    ESPECIALLY LOW PLACES.WEAR SCBA FOR LG SPILLS.REMOVE OPEN FLAMES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID BREATHING VAPORS.AVOID LIQ
    CONTACT W/SKIN/EYES.USE W/SUFFICIENT VENTILATION TO KEEP EMPLOYEE
    EXPO BELOW RECOMMENDED LIMITS.
Other Precautions:STORE IN CLEAN,DRY AREA.DO NOT HEAT ABOVE 125F.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:UNDER NORMAL MFG CONDITIONS NO RESPIRATORY
    PROTECTION IS REQUIRED WHEN USING THIS PRODUCT.SELF-CONTAINED
    BREATHING APPARATUS (SCBA) IS REQUIRED IF SPILL OCCURS.
Ventilation:NORMAL VENTI FOR STD MFG PROCEDURES.LOC EXH SHOULD BE USED
    WHEN LG AMTS RELEASED.MECH VENTI SHOULD BE USED IN LOW PLACES
Protective Gloves:IMPERVIOUS GLOVES
Eye Protection:CHEM SPLASH GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:FOLLOW GOOD HYGENIC PRACTICES.
Supplemental Safety and Health
HEALTH HAZ:PALPITATIONS,INADEQUATE CIRCULATION,ABNORMAL KIDNEY FUNCTION
    AS DETECTED BY LAB TEST;FATALITY FRM GROSS
    OVEREXPO.1STAID:CATECHOLAMINE DRUGS SUCH AS EPINEPHRINE SHOULD BE
    USED W/SPECIAL CAUT ION IN SITUATIONS OF EMERG LIFE SUPPORT.
    AUTODECOM TEMP:DICHLORODIFLUOROMETHAND:<760C;DIFLUOROETHANE:<445C.

==================  Physical/Chemical Properties  ==================

HCC:G3
Boiling Pt:B.P. Text:-27F,-33C
Decomp Temp:Decomp Text:SUPPLEMENTA
Vapor Pres:232PSI@54C
Vapor Density:3.7
Spec Gravity:1.16G/CC @25C
Evaporation Rate & Reference:LESS THAN 1, CCL4=1
Appearance and Odor:LIQUIFIED GAS, COLORLESS, SLIGHT ETHEREAL, CLEAR
    APPEARANCE.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE WITH ALKALI OR ALKALINE EARTH METALS-POWDERED AL, ZN, BE,
    ETC.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:DECOMP PROD-HAZ.CAN BE DECOMPOSED BY
    HI TEMP(OPN FLAME,GLOW METAL SURFACES,ETC)FORMING HCL OR CF
    ACIDS,CARBONYL HALIDES.

====================  Disposal Considerations  ====================

Waste Disposal Methods:COMPLY WITH LOCAL, STATE AND FEDERAL
    REGULATIONS. RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED WASTE
    DISPOSAL FACILITY. FREON 12 COMPONENT IS CERCLA HZ SUBSTANCE &
    TOXIC CHEMICAL. RQ FREON 12:5000  LBS/2270 KG.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.