DU PONT E I DE NEMOURS & CO INC -- FREON T-B1 HIGH VOLATILITY COOLANT -- 6850-00K001498
=====================  Product Identification  =====================

Product ID:FREON T-B1 HIGH VOLATILITY COOLANT
MSDS Date:05/01/1989
FSC:6850
NIIN:00K001498
MSDS Number: BMDYV
=== Responsible Party ===
Company Name:DU PONT E I DE NEMOURS & CO INC
Address:1007 MARKET STREET
Box:1635
City:WILMINGTON
State:DE
ZIP:19899
Country:US
Info Phone Num:800-441-3637(MEDICAL) OR CHEMTREC
Emergency Phone Num:800-441-7515
CAGE:18873
=== Contractor Identification ===
Company Name:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873

=============  Composition/Information on Ingredients  =============

Ingred Name:1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113)  (SARA
    III)
CAS:76-13-1
RTECS #:KJ4000000
Fraction by Wt: 98.6%
Other REC Limits:NONE SPECIFIED
OSHA PEL:1000PPM/1250STEL
ACGIH TLV:1000PPM/1250STEL9192
Ozone Depleting Chemical:1

Ingred Name:2-BUTOXYETHANOL
CAS:111-76-2
RTECS #:KJ8575000
Fraction by Wt: 1.4%
Other REC Limits:NONE SPECIFIED
OSHA PEL:S, 50 PPM
ACGIH TLV:S, 25 PPM; 9293

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD 50 ORAL RAT 43000 MG/KG
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF HIGH CONCENTRATIONS OF
    VAPOR IS HARMFUL AND MAY CAUSE HEART IRREGULARITIES,
    UNCONSCIOUSNESS OR DEATH. INTENTIONAL MISUSE CAN BE FATAL. VAPOR
    REDUCES OXYGEN AVAILABLE FOR BREATHING AND IS  HEAVIER THAN AIR.
    PRODUCT CAUSES EYE AND SKIN IRRITATION.
Explanation of Carcinogenicity:FREON 113 IS NOT LISTED AS A CARCINOGEN
    BY IARC, NTP OR OSHA.
Effects of Overexposure:EYE/SKIN-MAY INCLUDE EYE IRRITATION WITH
    DISCOMFORT, TEARING OR BLURRED VISION; OR SKIN IRRITATION WITH
    DISCOMFORT OR RASH. INHALE-MAY CAUSE TEMPORARY NERVOUS SYSTEM
    DEPRESSION, DIZZINESS, HEADACHE, C ONFUSION, INCOORDINATION, LOSS
    OF CONSCIOUSNESS, IRREGULAR PULSE, PALPITATIONS OR INADEQUATE
    CIRCULATION, OR FATALITY.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PREEXISTING
    DISEASES OF THE CENTRAL NERVOUS OR CARDIOVASCULAR SYSTEM MAY HAVE
    INCREASED SUSCEPTIBILITY TO THE TOXICITY OF EXCESSIVE EXPOSURE.

=======================  First Aid Measures  =======================

First Aid:INHALE- IMMEDIATELY REMOVE TO FRESH AIR. KEEP PERSON CALM. IF
    NOT BREATHING, GIVE ARTIFICIAL RESPIRATION.IF BREATHING IS
    DIFFICULT, GIVE OXYGEN. CALL A PHYSICIAN. EYE-IMMEDIATELY FLUSH
    WITH WATER. CAL L A PHYSICIAN. SKIN-FUSH WITH WATER AFTER EXCESSIVE
    CONTACT. ORAL-NO SPECIFIC INTERVENTION IS INDICATED AS THE COMPOUND
    IS NOT LIKELY TO BE HAZARDOUS BY INGESTION. DO NOT INDUCE VOMITING.
    SEE A DOCTOR

=====================  Fire Fighting Measures  =====================

Flash Point Method:TOC
Flash Point:WILL NOT BURN.
Autoignition Temp:Autoignition Temp Text:NONE
Extinguishing Media:MEDIA APPROPRIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:SELF CONTAINED BREATHING APPARATUS IS REQUIRED
    IF DRUMS RUPTURE & CONTENTS ARE SPILLED UNDER FIRE CONDITIONS. COOL
    FIRE EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:DRUMS MAY RUPTURE UNDER FIRE CONDITIONS.
    DECOMPOSITION MAY OCCUR.

==================  Accidental Release Measures  ==================

Spill Release Procedures:DIKE SPILL. SOAK UP WITH SAND, OIL DRY OR
    OTHER ABSORBENT MATERIAL. DO NOT FLUSH TO SEWER. KEEP UPWIND OF
    LEAK-EVACUATE UNTIL VAPORS HAVE DISPERSED.. USE SELF-CONTAINED
    BREATHING APPARATUS TO ENTER AR EA.
Neutralizing Agent:NONE

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A CLEAN, DRY AREA. DO NOT
    HEAT ABOVE 125F.
Other Precautions:AVOID CONTACT OF LIQUID WITH EYES & PROLONGED SKIN
    EXPOSURE. AVOID BREATHING HIGH CONCENTRATIONS OF VAPORS. USE WITH
    SUFFICIENT VENTILATION TO KEEP EMPLOYEE EXPOSURE BELOW RECOMMENDED
    LIMITS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED FOR ADEQUATELY VENTED WORK
    SITUATIONS. FOR ACCIDENTAL OR NON-VENTILATED SITUATIONS, USE A
    SELF-CONTAINED BREATHING APPARATUS OR SUPPLIED-AIR RESPIRATOR,
    APPROVED BY NIOSH.
Ventilation:USE ONLY WITH ADEQUATE VENTILATION.
Protective Gloves:BUTYL RUBBER GLOVES.
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:HAVE AVALIABLE AND WEAR AS APPROPIATE:
    COVERALLS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NOTE TO PHYSICIAN: BECAUSE OF POSSIBLE DISTURBANCES OF CARDIAC RHYTHM,
    CATECHOLAMINE DRUGS, SUCH AS EPINEPHRINE, SHOULD BE USED WITH
    SPECIAL CAUTION IN SITUATIONS OF EMERGENCY LIFE SUPPORT.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:118F,48C
Vapor Pres:274
Vapor Density:6.5
Spec Gravity:1.55
pH:7
Evaporation Rate & Reference:>1 (CCL*4=1)
Solubility in Water:<1.4%
Appearance and Odor:CLEAR, COLORLESSS, LIQUID, SLIGHT ETHEREAL ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS (POWERED ALUMINUM, ZINC, BERYLLIUM,
    ETC.).
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:DECOMPOSED BY HIGH TEMPERATURES (OPEN
    FLAMES, GLOWING METAL SURFACES, ETC.) FORMING HYDROCHLORIC AND
    HYDROFLUORIC ACIDS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:COMPLY WITH FEDERAL, STATE AND LOCAL
    REGULATIONS. REMOVE TO A PERMITTED WASTE DISPOSAL FACILITY. EPA
    HAZARDOUS WASTE NOS. F001 AND F002 MAY APPLY TO WASTE MATERIALS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.