DU PONT E I DE NEMOURS & CO INC -- FREON T-B1 HIGH VOLATILITY COOLANT -- 6850-00K001498
===================== Product Identification =====================
Product ID:FREON T-B1 HIGH VOLATILITY COOLANT
MSDS Date:05/01/1989
FSC:6850
NIIN:00K001498
MSDS Number: BMDYV
=== Responsible Party ===
Company Name:DU PONT E I DE NEMOURS & CO INC
Address:1007 MARKET STREET
Box:1635
City:WILMINGTON
State:DE
ZIP:19899
Country:US
Info Phone Num:800-441-3637(MEDICAL) OR CHEMTREC
Emergency Phone Num:800-441-7515
CAGE:18873
=== Contractor Identification ===
Company Name:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873
============= Composition/Information on Ingredients =============
Ingred Name:1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA
III)
CAS:76-13-1
RTECS #:KJ4000000
Fraction by Wt: 98.6%
Other REC Limits:NONE SPECIFIED
OSHA PEL:1000PPM/1250STEL
ACGIH TLV:1000PPM/1250STEL9192
Ozone Depleting Chemical:1
Ingred Name:2-BUTOXYETHANOL
CAS:111-76-2
RTECS #:KJ8575000
Fraction by Wt: 1.4%
Other REC Limits:NONE SPECIFIED
OSHA PEL:S, 50 PPM
ACGIH TLV:S, 25 PPM; 9293
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD 50 ORAL RAT 43000 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF HIGH CONCENTRATIONS OF
VAPOR IS HARMFUL AND MAY CAUSE HEART IRREGULARITIES,
UNCONSCIOUSNESS OR DEATH. INTENTIONAL MISUSE CAN BE FATAL. VAPOR
REDUCES OXYGEN AVAILABLE FOR BREATHING AND IS HEAVIER THAN AIR.
PRODUCT CAUSES EYE AND SKIN IRRITATION.
Explanation of Carcinogenicity:FREON 113 IS NOT LISTED AS A CARCINOGEN
BY IARC, NTP OR OSHA.
Effects of Overexposure:EYE/SKIN-MAY INCLUDE EYE IRRITATION WITH
DISCOMFORT, TEARING OR BLURRED VISION; OR SKIN IRRITATION WITH
DISCOMFORT OR RASH. INHALE-MAY CAUSE TEMPORARY NERVOUS SYSTEM
DEPRESSION, DIZZINESS, HEADACHE, C ONFUSION, INCOORDINATION, LOSS
OF CONSCIOUSNESS, IRREGULAR PULSE, PALPITATIONS OR INADEQUATE
CIRCULATION, OR FATALITY.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PREEXISTING
DISEASES OF THE CENTRAL NERVOUS OR CARDIOVASCULAR SYSTEM MAY HAVE
INCREASED SUSCEPTIBILITY TO THE TOXICITY OF EXCESSIVE EXPOSURE.
======================= First Aid Measures =======================
First Aid:INHALE- IMMEDIATELY REMOVE TO FRESH AIR. KEEP PERSON CALM. IF
NOT BREATHING, GIVE ARTIFICIAL RESPIRATION.IF BREATHING IS
DIFFICULT, GIVE OXYGEN. CALL A PHYSICIAN. EYE-IMMEDIATELY FLUSH
WITH WATER. CAL L A PHYSICIAN. SKIN-FUSH WITH WATER AFTER EXCESSIVE
CONTACT. ORAL-NO SPECIFIC INTERVENTION IS INDICATED AS THE COMPOUND
IS NOT LIKELY TO BE HAZARDOUS BY INGESTION. DO NOT INDUCE VOMITING.
SEE A DOCTOR
===================== Fire Fighting Measures =====================
Flash Point Method:TOC
Flash Point:WILL NOT BURN.
Autoignition Temp:Autoignition Temp Text:NONE
Extinguishing Media:MEDIA APPROPRIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:SELF CONTAINED BREATHING APPARATUS IS REQUIRED
IF DRUMS RUPTURE & CONTENTS ARE SPILLED UNDER FIRE CONDITIONS. COOL
FIRE EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:DRUMS MAY RUPTURE UNDER FIRE CONDITIONS.
DECOMPOSITION MAY OCCUR.
================== Accidental Release Measures ==================
Spill Release Procedures:DIKE SPILL. SOAK UP WITH SAND, OIL DRY OR
OTHER ABSORBENT MATERIAL. DO NOT FLUSH TO SEWER. KEEP UPWIND OF
LEAK-EVACUATE UNTIL VAPORS HAVE DISPERSED.. USE SELF-CONTAINED
BREATHING APPARATUS TO ENTER AR EA.
Neutralizing Agent:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A CLEAN, DRY AREA. DO NOT
HEAT ABOVE 125F.
Other Precautions:AVOID CONTACT OF LIQUID WITH EYES & PROLONGED SKIN
EXPOSURE. AVOID BREATHING HIGH CONCENTRATIONS OF VAPORS. USE WITH
SUFFICIENT VENTILATION TO KEEP EMPLOYEE EXPOSURE BELOW RECOMMENDED
LIMITS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE REQUIRED FOR ADEQUATELY VENTED WORK
SITUATIONS. FOR ACCIDENTAL OR NON-VENTILATED SITUATIONS, USE A
SELF-CONTAINED BREATHING APPARATUS OR SUPPLIED-AIR RESPIRATOR,
APPROVED BY NIOSH.
Ventilation:USE ONLY WITH ADEQUATE VENTILATION.
Protective Gloves:BUTYL RUBBER GLOVES.
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:HAVE AVALIABLE AND WEAR AS APPROPIATE:
COVERALLS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NOTE TO PHYSICIAN: BECAUSE OF POSSIBLE DISTURBANCES OF CARDIAC RHYTHM,
CATECHOLAMINE DRUGS, SUCH AS EPINEPHRINE, SHOULD BE USED WITH
SPECIAL CAUTION IN SITUATIONS OF EMERGENCY LIFE SUPPORT.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:118F,48C
Vapor Pres:274
Vapor Density:6.5
Spec Gravity:1.55
pH:7
Evaporation Rate & Reference:>1 (CCL*4=1)
Solubility in Water:<1.4%
Appearance and Odor:CLEAR, COLORLESSS, LIQUID, SLIGHT ETHEREAL ODOR.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS (POWERED ALUMINUM, ZINC, BERYLLIUM,
ETC.).
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:DECOMPOSED BY HIGH TEMPERATURES (OPEN
FLAMES, GLOWING METAL SURFACES, ETC.) FORMING HYDROCHLORIC AND
HYDROFLUORIC ACIDS.
==================== Disposal Considerations ====================
Waste Disposal Methods:COMPLY WITH FEDERAL, STATE AND LOCAL
REGULATIONS. REMOVE TO A PERMITTED WASTE DISPOSAL FACILITY. EPA
HAZARDOUS WASTE NOS. F001 AND F002 MAY APPLY TO WASTE MATERIALS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.