ACE HARDWARE CORP/PAINT DIV -- 113A150 7-STAR RUSTIC TONES OIL (SUPDAT) -- 8010-00N028909
=====================  Product Identification  =====================

Product ID:113A150 7-STAR RUSTIC TONES OIL (SUPDAT)
MSDS Date:10/01/1986
FSC:8010
NIIN:00N028909
MSDS Number: BMYMF
=== Responsible Party ===
Company Name:ACE HARDWARE CORP/PAINT DIV
Address:21901 SOUTH CENTRAL AVENUE
City:MATTESON
State:IL
ZIP:60443
Country:US
Info Phone Num:312-720-0600
Emergency Phone Num:312-720-0600
CAGE:ACEHA
=== Contractor Identification ===
Company Name:ACE HARDWARE CORPORATION
Address:21901 SOUTH CENTRAL AVENUE
City:MATTESON
State:IL
ZIP:60443
Country:US
Phone:708-720-0600
CAGE:ACEHA

=============  Composition/Information on Ingredients  =============

Ingred Name:MINERAL SPIRITS. VP:2
CAS:64742-47-8
Fraction by Wt: 65.0%
OSHA PEL:500 PPM (MFR)
ACGIH TLV:100 PPM

Ingred Name:MINERAL SPIRITS (140 FLASH). VP:0.5
CAS:64742-47-8
Fraction by Wt: 10.0%
OSHA PEL:500 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHAL IS ANESTHETIC. IRRITATION OF
    RESP TRACT OR NERVOUS SYSTEM DEPRESSION. HEADAHCE, DIZZINESS,
    NAUSEA, CONFUSION, UNCONSCIOUSNESS, OR COMA. SKIN OR EYE CONTACT:
    PRIMARY IRRITATION. CHRONIC: REPORTS  HAVE ASSOC REPEATED AND
    PRLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN
    & NERVOUS SYSTEM DAMAGE.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE FROM EXPOSURE, RESTORE BREATHING, KEEP WARM AND
    QUIET. NOTIFY PHYSICIAN. EYE:FLUSH IMMED WITH RUNNING WATER FOR AT
    LEAST 15 MINUTES. SKIN:WASH WITH SOAP AND WATER AND APPLY SKIN
    CREAM. NO TIFY PHYSICIAN IN ALL CASES. INGEST:CALL MD IMMEDIATELY .

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:105F,41C
Lower Limits:0.9
Extinguishing Media:FOAM, "ALCOHOL" FOAM, CO2, DRY CHEMICAL
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
    DURING EMER CNDTNS OVEREXPOS TO DECOMP PROD MAY CAUSE HLTH HAZ.
    SYMP MAY NOT BE IMMED APPARENT. (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHLY CLSD. ISOLATE FROM
    HEAT, ELECTRICAL EQUIP, SPARKS, & OPEN FLAME. HEAT MAY CAUSE PRESS
    TO BUILD-UP IN CLSD CNTNRS, WATER MAY BE USED TO COOL.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
    REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CONTENTS ARE COMBUST, KEEP AWAY FROM
    HEAT AND OPEN FLAME. USE ONLY WITH ADEQUATE VENT. AVOID BRTHG VAP &
    SPRAY MIST. AVOID CONTACT WITH SKIN AND EYES.
Other Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE. DO NOT
    TRANSFER CONTENTS TO OTHER CONTAINERS FOR STOR. DO NOT TAKE
    INTERNALLY. KEEP OUT OF REACH OF CHILDREN. CONSULT NFPA CODE. USE
    APPROVED BONDING AND GROUNDI NG PROCEDURES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF ENGINEERING AND ADMINISTRATIVE CONTROLS OF
    AIR CONTAMINANTS ARE NOT POSSIBLE, USE RESPIRATORY DEVICES APPROVED
    BY NIOSH/ MSHA FOR PROTECTION AGAINST SPRAY MIST AND VAPORS.
Ventilation:LOCAL EXHAUST PREFERABLE. MECHANICAL (GENERAL) EXHAUST
    ACCEPTABLE. SPECIAL VENT REQ TO KEEP BELOW TLV AND LEL.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:REMOVE AND WASH CONTAMINATED CLOTHING, DISCARD
    CONTAMINATED SHOES. WASH HANDS AFTER USING.
Supplemental Safety and Health
MFR TRADE NAME/PART #:SEMI-TRANSPARENT STAIN NATURAL CEDAR. FIRE FIGHT
    PROC:OBTAIN MD ATTENTION. WATER SPRAY MAY BE INEFFECTIVE. WATER MAY
    BE USED TO COOL CONTAINERS TO PREVENT PRESSURE BUILD-UP AND P
    OSSIBLE AUTO IGNITION OR EXPLOSION WHENEXPOSED TO EXTREME HEAT.

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:>308F,>153C
Vapor Density:HVR/AIR
Spec Gravity:0.863 
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:82.9

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:HIGH TEMPERATURES, OPEN FLAME.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
    MONOXIDE

====================  Disposal Considerations  ====================

Waste Disposal Methods:INCINERATE IN APPROVED FACILITY. DO NOT
    INCINERATE CLOSED CONTAINER. DISPOSE OF IN ACCORDANCE WITH FEDERAL,
    STATE, AND LOCAL REGULATIONS REGARDING POLLUTION.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.