ACE HARDWARE CORP/PAINT DIV -- 133A110, 5-STAR OIL EXTERIOR REDWOOD STAIN -- 8010-00N028991
=====================  Product Identification  =====================

Product ID:133A110, 5-STAR OIL EXTERIOR REDWOOD STAIN
MSDS Date:10/01/1986
FSC:8010
NIIN:00N028991
MSDS Number: BMYPD
=== Responsible Party ===
Company Name:ACE HARDWARE CORP/PAINT DIV
Address:21901 SOUTH CENTRAL AVENUE
City:MATTESON
State:IL
ZIP:60443
Country:US
Info Phone Num:312-720-0600
Emergency Phone Num:312-720-0600
CAGE:ACEHA
=== Contractor Identification ===
Company Name:ACE HARDWARE CORPORATION
Address:21901 SOUTH CENTRAL AVENUE
City:MATTESON
State:IL
ZIP:60443
Country:US
Phone:708-720-0600
CAGE:ACEHA

=============  Composition/Information on Ingredients  =============

Ingred Name:KEROSENE (PETROLEUM), HYDROTREATED; (MINERAL SPIRITS 140
    FLASH). VP: 0.5
CAS:64742-47-8
RTECS #:OA5504000
Fraction by Wt: 74%
OSHA PEL:500 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

Ingred Name:KEROSENE (PETROLEUM), HYDROTREATED; (MINERAL SPIRITS). VP:
    2
CAS:64742-47-8
RTECS #:OA5504000
Fraction by Wt: 5%
OSHA PEL:500 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION IS ANESTHETIC. IRRITATION
    OF RESPIRATORY TRACT OR NERVOUS SYSTEM DEPRESSION. HEADACHE,
    DIZZINESS, NAUSEA, CONFUSION, UNCONSCIOUSNESS OR COMA. SKIN/EYE:
    PRIMARY IRRITATION. REPORTS HAVE ASSO C RPTD & PRLNGD OCCUP OVEREXP
    TO SOLV W/PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL: REMOVE FROM EXPOSURE, RESTORE BREATHING, KEEP WARM AND
    QUIET, CALL MD. EYES: FLUSH IMMEDIATELY WITH RUNNING WATER FOR AT
    LEAST 15 MINUTES. SKIN: WASH WITH SOAP AND WATER AND APPLY SKIN
    CREAM. C ALL MD IN ALL CASES. INGEST: CALL MD IMMEDIATELY .

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:105F,41C
Lower Limits:0.9%
Extinguishing Media:FOAM, "ALCOHOL" FOAM, CO2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
    .DURING EMER CNDTNS OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ.
    SYMP MAY NOT BE IMMED APPARENT. (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
    HEAT, ELEC EQUIP, SPARKS, AND OPEN FLAME. HEAT MAY CAUSE PRESSURE
    BUILD-UP IN CLSD CNTNRS, WATER MAY BE USED TO COOL.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
    REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DOL STORAGE CATEGORY 2. CONTENTS ARE
    COMBUSTIBLE, KEEP AWAY FROM HEAT AND OPEN FLAME.
Other Precautions:USE ONLY W/ADEQ VENT. AVOID BREATHING VAPOR & SPRAY
    MIST. AVOID CONTACT W/SKIN & EYES. KEEP CONTAINER CLOSED WHEN NOT
    IN USE. DO NOT TRANSFER CONTENTS TO OTHER CONTAINERS FOR STORAGE.
    DO NOT TAKE INTE RNALLY. KEEP OUT OF REACH OF CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF ENGINEERING AND ADMINISTRATIVE CONTROLS OF
    AIR CONTAM ARE NOT POSSIBLE, USE RESPIRATORY DEVICES APPROVED BY
    NIOSH/MSHA FOR PROTECTION AGAINST SPRAY MIST AND VAPORS.
Ventilation:LOCAL EXHAUST PREF. MECHANICAL (GENERAL) EXHAUST
    ACCEPTABLE. SPECIAL VENT REQUIRED TO KEEP BELOW TLV AND LEL.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:REMOVE AND WASH CONTAMINATED CLOTHING, DISCARD
    CONTAMINATED SHOES. WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC: OBTAIN MEDICAL ATTENTION. WATER SPRAY MAY BE INEFT.
    WATER MAY BE USED TO COOL CLOSED CONTAINERS TO PREVENT PRESSURE
    BUILD-UP AND POSSIBLE AUTOIGNITION OR EXPLOSION WHEN EXPOSED TO EXT
    REME HEAT.

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:>300F,>149C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:0.9 
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:86.93

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:HIGH TEMPERATURES, OPEN FLAME.
Hazardous Decomposition Products:BY FIRE: CO2, CO.

====================  Disposal Considerations  ====================

Waste Disposal Methods:INCINERATE IN APPROVED FACILITY. DO NOT
    INCINERATE CLOSED CONTAINER. DISPOSE OF IN ACCORDANCE WITH FEDERAL,
    STATE AND LOCAL REGULATIONS REGARDING POLLUTION.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.