ICI POLYURETHANES GROUP -- RUBINATE M (POLYMERIC MDI) -- 8040-00N019876
===================== Product Identification =====================
Product ID:RUBINATE M (POLYMERIC MDI)
MSDS Date:08/17/1990
FSC:8040
NIIN:00N019876
MSDS Number: BNVGP
=== Responsible Party ===
Company Name:ICI POLYURETHANES GROUP
Address:286 MANTUA GROVE RD
City:WEST DEPTFORD
State:NJ
ZIP:08066
Country:US
Info Phone Num:609-423-8300 OR 302-886-3000
Emergency Phone Num:800-327-8633;800-424-9300(CHEMTREC)
CAGE:ICIPO
=== Contractor Identification ===
Company Name:ICI POLYURETHANES GROUP,RUBICON CHEM IS A DIV
Address:286 MANTUA GROVE ROAD
Box:City:WEST DEPTFORD
State:NJ
ZIP:08066
Country:US
Phone:302-866-3000
CAGE:ICIPO
============= Composition/Information on Ingredients =============
Ingred Name:ING 15:EXPOSURE I/A/W GOOD HYGIENE PRACTICE.
RTECS #:9999999ZZ
Ingred Name:WASTE DISP METH:I/A/W FEDERAL, STATE AND LOCAL REGULATIONS
.
RTECS #:9999999ZZ
Ingred Name:ISOCYANIC ACID, METHYLENEDI-P-PHENYLENE ESTER; (METHYLENE
BISPHENYL ISOCYANATE) (MDI) (SARA III)
CAS:101-68-8
RTECS #:NQ9350000
Fraction by Wt: 50%
OSHA PEL:0.02 PPM, C
ACGIH TLV:0.005 PPM
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Ingred Name:POLYMETHYLENEPOLYPHENYL ISOCYANATE; (SIMILAR STRUCTURE
OLIGOMERS)
CAS:9016-87-9
RTECS #:TR0350000
Fraction by Wt: 50%
Ingred Name:SUPP DATA:BE IMMED/DELAYED UP TO SEVERAL HRS AFTER
EXPOS.CHRONIC EXPOS MAY RSLT IN PERM DECREASE IN LUNG FUNCTION(ING
4)
RTECS #:9999999ZZ
Ingred Name:ING 3:OR LUNG INJURY.IN STUDY OF RATS EXPSD AT 6MG/M3 THERE
WAS SIGNIFICANT INCIDENCE OF BENIGN TUMOR OF LUNG (ING 5)
RTECS #:9999999ZZ
Ingred Name:ING 4:(ADENOMA) & 1 MALIGNANT TUMOR (ADENOCARCINOMA). INCR
INCIDENCE OF LUNG TUMORS IS ASSOC W/PRLNGD RESP IRRIT (ING 6)
RTECS #:9999999ZZ
Ingred Name:ING 5:& CONCURRENT ACCUMULATION OF YELLOW MATERIAL IN LUNG
WHICH OCCURRED THROUGHOUT THE STUDY.
RTECS #:9999999ZZ
Ingred Name:FIRST AID PROC:IF NOT BRTHG, GIVE ARTF RESP, PREF
MOUTH-TO-MOUTH. IF BRTHG LABORED, GIVE O*2. CALL MD.
RTECS #:9999999ZZ
Ingred Name:SPILL PROC:CARBONATE MAY BE SUBSTITUTED FOR AMMONIUM
HYDROXIDE). TREAT SPILL AREA W/DECONTAM SOLN, USING ABOUT (ING 9)
RTECS #:9999999ZZ
Ingred Name:ING 8:10 PARTS OF SOLUTION FOR EACH PART OF SPILL & ALLOW
IT TO REACT FOR AT LEAST 10 MINUTES. CARBON DIOXIDE (ING 10)
RTECS #:9999999ZZ
Ingred Name:ING 9:WILL BE EVOLVED, LEAVING INSOLUBLE POLYUREAS.
RTECS #:9999999ZZ
Ingred Name:VENT:OR FILTERS TO REDUCE ENVIRONMENTAL CONTAMINATION.
RTECS #:9999999ZZ
Ingred Name:PROT CLTHG:HAVE EXCELLENT RESISTANCE TO PERMEATION BY MDI.
PROT CLOTHING SHOULD BE SELECTED & USED I/A/W (ING 13)
RTECS #:9999999ZZ
Ingred Name:ING 12:"GUIDELINES FOR THE SELECTION OF CHEM PROT
CLTHG"PUBLISHED BY ACGIH. EYEWASH STATION, SAFETY SHOWER IN WORK
AREA.
RTECS #:9999999ZZ
Ingred Name:OTHER PREC:SHOULD BE IDENTIFIED THROUGH BASELINE & ANNUAL
EVALUATION & REMOVED FROM FURTHER EXPOS. MED EXAM (ING 15)
RTECS #:9999999ZZ
Ingred Name:ING 14:SHOULD INCLUDE MEDICAL HISTORY, VITAL CAPACITY &
FORCED EXPIRATORY VOLUME AT ONE SECOND. MINIMIZE (ING 16)
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50:(ORAL,RAT)>10,000 MG/KG.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:IRRIT OF MOUTH, PHARYNX,
ESOPHAGUS & STOMACH. EYE:WILL IRRIT FOLLOWING CNTCT. SKIN:SENSIT
&/OR IRRIT MAY DEVELOP AFTER RPTD &/OR PRLNGD CNTCT. MDI IN CORN
OIL INJECTED INTRADERMALLY IN GUINEA P IGS CAN ELICIT A RESP SENSIT
RXN. POTNTL FOR MDI TO INDUCE RESP SENSIT IN HUMANS & ANIMALS BY
INHAL IS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVENT
Effects of Overexposure:HLTH HAZ:WELL KNOWN; HOWEVER, NEW DATA
INDICATES THAT THIS EFT MAY BE INDUCED BY SKIN CNTCT. INHAL:VAPS &
AEROSOLS CAN IRRIT EYES, NOSE & RESP PASSAGES. SEVERE OVEREXPOS MAY
LEAD TO PULM EDEMA. MDI CA N INDUCE RESP SENSIT W/ASTHMA-LIKE SYMPS
SIMILAR TO THOSE INDUCED BY TDI(TOLUENE DIISOCYANATE). SYMPS
INCLUDE(SUPP DATA)
Medical Cond Aggravated by Exposure:INDIVIDUALS W/EXISTING RESPIRATORY
DISEASE, SUCH AS CHRONIC BRONCHITIS, EMPHYSEMA OR ASTHMA.
SENSITIZED INDIVIDUALS SHOULD BE REMOVED FROM ANY FURTHER EXPOSURE.
======================= First Aid Measures =======================
First Aid:SKIN:WASH OFF W/PLENTY OF SOAP & WATER. IF REDNESS,
ITCHING/BURNING SENSATION DEVELOPS, GET MD. EYE:IMMED FLUSH
W/PLENTY OF WATER FOR AT LEAST 15 MIN. IF REDNESS, ITCHING/BURNING
SENSATION DEVELOPS, H AVE EYES EXAMINED & TREATED BY MED PERS.
INGEST:GIVE 1-2 GLASSES OF WATER TO DRINK. IF GI SYMPS DEVELOP,
CALL MD. (NEVER GIVE ANYTHING BY MOUTH TO UNCON PERS.) INHAL:REMOVE
TO FRESH AIR. (ING 7)
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:425F,218C
Extinguishing Media:DRY CHEMICAL, FOAM, CARBON DIOXIDE, HALOGENATED
AGENTS. IF WATER USED, USE VERY LARGE QUANTITIES.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . REACTION BETWEEN WATER & HOT ISOCYANATE MAY
BE VIGOROUS.
Unusual Fire/Explosion Hazard:WATER CONTAMINATION WILL PRODUCE CARBON
DIOXIDE. DO NOT RESEAL CONTAMINATED CONTAINERS AS PRESSURE BUILDUP
MAY RUPTURE THEM.
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR PROT DURING CLEANUP. SOAK UP MATL
W/ABSORB & SHOVEL INTO CHEM WASTE CNTNR. COVER CNTNR BUT DO NOT
SEAL & REMOVE FROM WORK AREA. PREPARE DECONTAM SOLN OF 0.2-0.5% LIQ
DETERGENT & 3-8% CONC AMMONIU M HYDROXIDE IN WATER (5-10% SODIUM
(ING8)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN TIGHTLY SEALED CNTNRS TO
PROTECT FROM ATMOSPHERIC MOISTURE. STORE IN COOL AREA. PVNT SKIN &
EYE CNTCT. AVOID BRTHG VAPS/AEROSOLS.
Other Precautions:OBSERVE TLV LIMITATIONS. SENSITIZED INDIVIDUAL SHOULD
NOT BE EXPOSED TO PROD WHICH CAUSED SENSIT. INDIVIDUALS W/EXISTING
RESP DISEASE SUCH AS CHRONIC BRONCH, EMPHYSEMA/ASTHMA SHOULD NOT BE
EXPOSED TO ISOCYANATES. THESE INDIVIDUALS (ING 14)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF AIRBORNE CONCS EXCEED/EXPECTED TO EXCEED TLV,
USE NIOSH/MSHA APPRVD:POS PRESS SUPPLIED AIR RESP W/FULL
FACEPIECE/AIR SUPPLIED HOOD. FOR EMER USE POS PRESS SCBA. AIR
PURIFYING (CARTRIDGE TYPE) RESP NOT APPRVD FOR PROT AGAINST
ISOCYANATES.
Ventilation:IF NEEDED, USE LOCAL EXHST VENT TO KEEP AIRBORNE CONCS
BELOW TLV. EXHST AIR MAY NEED TO BE CLEANED BY SCRUBBERS (ING 11)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEM WORK GOG & FULL LENGTH FSHLD.
Other Protective Equipment:APRON, ARM COVERS/FULL BODY SUIT. BUTYL
RUBBER, NITRILE RUBBER, SARANEX COATED TYVEK & SOME NEOPRENE
GARMENTS (ING 12)
Work Hygienic Practices:WORKERS SHOULD SHOWER & CHANGE TO FRESH
CLOTHING AFTER EACH SHIFT. WASH CONTAMINATED CLOTHING BEFORE
REWEARING.
Supplemental Safety and Health
VP:<0.0001 @ 20C. MATLS TO AVOID:RXN W/WATER VERY SLOW <50C BUT
ACCELERATED AT HIGHER TEMPS & IN PRESENCE OF ALKALIES, TERTIARY
AMINES & METAL CMPDS. SOME RXN CAN BE VIOLENT. CNDTNS(POLYM):
EVOLUTION OF CO*2 GAS MAY RUPTURE CLOSED CNTNRS. EFTS OF
OVERXP:CHRONIC COUGH, TIGHTNESS OF CHEST W/DFCLTY IN BRTHG & MAY
(ING 3)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:646F,341C
Decomp Temp:Decomp Text:646F,341C
Vapor Pres:SUPP DATA
Vapor Density:8.6
Spec Gravity:1.2
Solubility in Water:REACTS
Appearance and Odor:DARK BROWN, VISCOUS LIQUID W/SLIGHT ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
WILL REACT W/MATLS CONTAINING ACTIVE HYDROGENS, SUCH AS WATER, ALCOHOL,
AMMONIA, AMINES, ALKALIES & ACIDS. (SUPP DATA)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:COMBUSTION PRODUCTS: CO*2, CO, NO*X,
NH*3. TRACE AMOUNTS OF HCN.
Conditions to Avoid Polymerization:HIGH TEMPS IN PRESENCE OF ALKALIES,
TERTIARY AMINES & METAL CMPDS WILL ACCELERATE POLYMERIZATION.
POSSIBLE (SUPP DATA)
==================== Disposal Considerations ====================
Waste Disposal Methods:SLOWLY STIR ISOCYANATE WASTE INTO DECONTAM SOLN
USING 10 PARTS OF SOLN FOR EACH PART OF ISOCYANATE. LET STAND FOR
48 HRS, ALLOWING EVOLVED CO*2 TO VENT AWAY. NEUT WASTE. NEITHER
SOLID/LIQ PORTION HAZ WASTE UNDER RCRA, 40CFR261. DISPOSE OF (ING
17)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.