JPS ELASTOMERICS CORP -- THERMOPLASTIC POLYURETHANES -- 9330-00N041842
=====================  Product Identification  =====================

Product ID:THERMOPLASTIC POLYURETHANES
MSDS Date:09/08/1988
FSC:9330
NIIN:00N041842
MSDS Number: BSQYS
=== Responsible Party ===
Company Name:JPS ELASTOMERICS CORP
Address:395 PLEASANT ST
City:NORTHAMPTON
State:MA
ZIP:01060-0658
Country:US
Info Phone Num:413-586-8750
Emergency Phone Num:413-586-8750;413-586-8757
CAGE:JPSEL
=== Contractor Identification ===
Company Name:JPS ELASTOMERICS CORP
Address:395 PLEASANT ST
Box:City:NORTHAMPTON
State:MA
ZIP:01060-0658
Country:US
Phone:413-586-8750
CAGE:JPSEL

=============  Composition/Information on Ingredients  =============

Ingred Name:CHROMIUM (III) OXIDE (2:3); (CHROMIUM GREEN)
CAS:1308-38-9
RTECS #:GB6475000
Fraction by Wt: 1%
Other REC Limits:0.25 MG/M3
OSHA PEL:0.5 MG/M3
ACGIH TLV:0.5 MG/M3

Ingred Name:CHROMIC ACID, LEAD(2+)SALT(1:1); (CHROME YELLOW)
CAS:7758-97-6
RTECS #:GB2975000
Fraction by Wt: 1%
OSHA PEL:0.1 MG/M3 STEL, C
ACGIH TLV:0.05 MG/M3

Ingred Name:SUPDAT: LEAD COMPPOUNDS (CHROME YELLOW) APPEAR ON THE NAV
    OCC CHEM REPROD HAZ LIST. SEEK CONSULT FROM APPROP HLTH (ING 4
RTECS #:9999999ZZ
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:(ING 3) PROFESSIONALSS CONCERNING LATES HAZ LIST INFO &
    SAFE HNDLINNNG & EXPOSURE INFO .
RTECS #:9999999ZZ
Other REC Limits:NONE RECOMMENDED
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:ING 1 & 2: ACUTE EFTS INCL IRRIT OF
    SKIN, EYES, & RESP TRACT. CHRONIC OVEREXP MAY RSLT IN SENSIT DERM.
    UNDER AMBIENT & USE CNDTNS, THESE PROD PRESENT NO EXPOS POTNTL AS
    CHROMIUM CMPDS ARE BOND IN MATR IX OF PROD. HOWEVER, HEAT
    PROCESSING @ MELT TEMPS (300-400F) MAY CAUSE SM AMTS OF CHROMIUM
    CMPDS TO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:LEAD CHROMATE: GROUP 1 (IARC VOL49, P49,
    '90), KNOWN CARCINOGEN (NTP 6TH ANN RPT, '91).
Effects of Overexposure:HLTH HAZ: BE REL. IN THIS SITUATION, INHAL OF
    PROCESSING BY PROD MUST BE AVOIDED THRU USE OF GOOD VENT.
    MEASUREMENTS CONDUCTED BY STEVENS @ TEMP OF 375F INDICATE NO
    CHROMATES WERE DETECTABLE. HEAT PRO CESSING @/ABOVE DECOMP PT MAY
    REL PROD,INCL ISOCYANATE, MDI, WHICH MAY RSLT IN IRRIT OF RESP
    TRACT & EYES, (SUPP DATA)
Medical Cond Aggravated by Exposure:RESPIRATORY TRACT PROBLEMS.

=======================  First Aid Measures  =======================

First Aid:SKIN: FLUSH IMMEDIATELY WITH WATER AND SEEK MEDICAL ATTENTION
    FOR THERMAL BURN. INHAL: REMOVE TO FRESH AIR. IF BREATHING HAS
    STOPPED RESTORE BREATHING AND GET MEDICAL ATTENTION. INGEST: CALL
    MD IMMED  . EYE: IMMEDIATELY FLUSH WITH POTABLE WATER FOR A MINIMUM
    OF 15 MINUTES, SEEK ASSISTANCE FROM MD .

=====================  Fire Fighting Measures  =====================

Flash Point:>740F,>393C
Extinguishing Media:WATER, ABC DRY CHEMICAL, PROTEIN AIR FOAMS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT . CARBON DIOXIDE EXTINGUISHERS MAY BE
    INADEQUATE.
Unusual Fire/Explosion Hazard:THESE POLYMERS ARE COMBUSTIBLE WHEN
    FORCED TO BURN AND MAY EMIT TOXIC VAPORS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VACUUM OR SWEEP INTO A CLOSED CONTAINER FOR
    REUSE OR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP DRY TO ENSURE QUALITY OF PROD. NO
    HAZ PRESENTED @ AMBIENT STOR/PROCESS CNDTNS. HOWEVER, @ ELEVATED
    TEMPS (>300-400F), TOX VAPS MAY BE EVOLVED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NOT REQUIRED FOR NORMAL, AMBIENT USE. FOR
    PROCESSING ABOVE MELT POINT, NIOSH/MSHA APPROVED SUPPLIED AIR
    RESPIRATORS SHOULD NOT BE USED.
Ventilation:LOC EXHAUST: WHEN MELT PROCESSING TO REMOVE VAPS. EXHAUST
    HOODS SHOULD MAINTAIN A MIN OF 100 LFM FACE (SUPP DATA)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APRV CHEMICAL WORKERS GOGGLES (FP N
Other Protective Equipment:ARM PROTECITON REQUIRED WHEN HANDLING HOT
    PRODUCT.
Work Hygienic Practices:MAINTAIN GOOD PERSONAL HYGIENE AS STANDARD GOOD
    WORK PRACTICE.
Supplemental Safety and Health
SPEC GRAV: 1.05-1.35(H*2O=1). EFTS OF OVEREXP: CHEST TIGHTNESS,
    COUGHING, HEADACHE & DYSPNEA. SENSIT W/SUBSEQUENT ASTHMA-LIKE
    ATTACKS MAY FOLLOW (ING 3) .VENT: VELOCITY. MECH (GEN): GOOD
    VENTILATION R ECOMMENDED.

==================  Physical/Chemical Properties  ==================

Melt/Freeze Pt:M.P/F.P Text:>300F,>149C
Spec Gravity:SUPP DATA
Solubility in Water:INSOLUBLE
Appearance and Odor:VARIOUS COLORS CORD, FILMS, PROFILES, SHEET, AND
    TUBING. VERY FAINT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE, HCN,
    OXIDES OF NITROGEN, ALIPHATIC AND AROMATIC HYDROCARBONS, INCLUDING
    MDI.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN A LICENSED LANDFILL OR BY
    INCINERATION IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.