GAS TECH INC. JOHNSON INSTRUMENT DIV -- FREON 12(R) (0-2,300 PPM) IN AIR -- 6830-00-935-9895
=====================  Product Identification  =====================

Product ID:FREON 12(R) (0-2,300 PPM) IN AIR
MSDS Date:08/11/1993
FSC:6830
NIIN:00-935-9895
MSDS Number: BTHVZ
=== Responsible Party ===
Company Name:GAS TECH INC. JOHNSON INSTRUMENT DIV
Address:8445 CENTRAL AVE
City:NEWARK
State:CA
ZIP:94560-3431
Country:US
Info Phone Num:510-794-6200
Emergency Phone Num:510-794-6200
CAGE:51906
=== Contractor Identification ===
Company Name:GAS TECH INC. JOHNSON INSTRUMENT DIV
Address:8445 CENTRAL AVE
Box:City:NEWARK
State:CA
ZIP:94560-3431
Country:US
Phone:510-794-6200
CAGE:51906

=============  Composition/Information on Ingredients  =============

Ingred Name:DICHLORODIFLUOROMETHANE  (SARA III)
CAS:75-71-8
RTECS #:PA8200000
Fraction by Wt: <0-0.23%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9394
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ozone Depleting Chemical:1

Ingred Name:AIR, REFRIGERATED LIQUID; AIR COMPRESSED (UN1002, DOT); AIR
    REFRIGERATED LIQUID (CRYOGENIC LIQUID) (UN1003) (DOT)
RTECS #:AX5271000
Fraction by Wt: 99.7%+
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION OF VERY HIGH
    CONCENTRATIONS MAY CAUSE IRREGULAR HERAT BEAT, ANGINA, DEATH.
    CHRONIC: NONE IDENTIFIED.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:NONE.
Medical Cond Aggravated by Exposure:CARDIOVASCULAR DISEASE.

=======================  First Aid Measures  =======================

First Aid:RESPIRATORY: PROVIDE FRESH AIR OR OXYGEN AND CONSULT
    PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE METHOD APPROPIATE TO SURROUNDING FIRE.
Fire Fighting Procedures:NONE.
Unusual Fire/Explosion Hazard:COMPRESSED GAS CYLINDERS MAY EXPLODE IN
    HEAT OF FIRE. WITHDRAW IMMEDIATELY IN CASE OF RISING SOUND FROM
    VENTING SAFETY DEVICE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE AND VENTILATE AREA.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY AREA. USE SAFE
    STORAGE PRACTICES FOR THE STORAGE OF COMPRESSED GAS CYLINDERS.
Other Precautions:USE SAFE HANDLING PRACTICES FOR THE HANDLING OF
    COMPRESSED GAS CYLINDERS. DO NOT PUNCTURE. EXPOSURE TO TEMPERATURES
    ABOVE 150 DEGREES F MAY OPERATE EXCESS-PRESSURE VALVE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NECESSARY.
Ventilation:RECOMMENDED.
Protective Gloves:SKIN PROTECTION NOT REQUIRED.
Eye Protection:SAFETY GLASSES RECOMMENDED.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE.

==================  Physical/Chemical Properties  ==================

HCC:G3
Vapor Density:1.0-1.01
Solubility in Water:SLIGHT
Appearance and Odor:GAS.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
SODIUM, POTASSIUM, BARIUM, MAGNESIUM OR ALUMINUM POWDERS, OIL IN HIGH
    PRESSURE EQUIPMENT.
Stability Condition to Avoid:NONE IDENTIFIED.
Hazardous Decomposition Products:HYDROGEN FLUORIDE, HYDROGEN CHLORIDE,
    PHOSGENE, CARBONYL FLUORIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:EMPTY CONTAINERS MAY BE DISCARDED AS METAL
    REFUSE, OBSERVING FEDERAL, STATE AND LOCAL REGULATIONS. DO NOT
    INCINERATE.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their