BRUNING PAINT COMPANY -- 305-00 WHITE, CARRIAGE HOUSE EXTERIOR OIL (SUP DAT) -- 8010-00N066874
=====================  Product Identification  =====================

Product ID:305-00 WHITE, CARRIAGE HOUSE EXTERIOR OIL (SUP DAT)
MSDS Date:07/01/1993
FSC:8010
NIIN:00N066874
MSDS Number: CBDXS
=== Responsible Party ===
Company Name:BRUNING PAINT COMPANY
Address:601 SOUTH HAVEN STREET
City:BALTIMORE
State:MD
ZIP:21224
Country:US
Info Phone Num:410-342-3636
Emergency Phone Num:410-342-3641
CAGE:EO376
=== Contractor Identification ===
Company Name:BRUNING PAINT COMPANY
Address:601 S. HAVEN STREET
City:BALTIMORE
State:MD
ZIP:21224
Country:US
Phone:800-424-9300(NIGHT)410-342-3636 DAY
CAGE:EO376
Company Name:KYANIZE PAINT
Address:601 S HAVEN ST
Box:City:BALTIMORE
State:MD
ZIP:21224
Country:US
Phone:800-368-2076
CAGE:85520

=============  Composition/Information on Ingredients  =============

Ingred Name:STODDARD SOLVENT
CAS:8052-41-3
RTECS #:WJ8925000
Fraction by Wt: 7.5-10%
OSHA PEL:500 PPM
ACGIH TLV:100 PPM

Ingred Name:TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (MAGNESIUM
    SILICATE)
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: 10-15%
OSHA PEL:20 MPPCF Z-3
ACGIH TLV:2 MG/M3 RDUST

Ingred Name:SOLVENT NAPHTHA (PETROLEUM), LIGHT AROMATIC; (HYDROCARBON
    SOLVENT)
CAS:64742-95-6
RTECS #:WF3400000
Fraction by Wt: 1-5%
OSHA PEL:2625 MG/M3 (MFR)
ACGIH TLV:525 MG/M3 (MFR)

Ingred Name:ZINC OXIDE (SARA 313) (CERCLA)
CAS:1314-13-2
RTECS #:ZH4810000
Fraction by Wt: 7.99%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST

Ingred Name:VOLATILE ORGANIC COMPOUND RANGE:1.45
RTECS #:9999999VO
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:EXPLO HAZS:SURFS. NEVER USE WELDING/CUTTING TORCH ON/NEAR
    CNTNR (EVEN EMPTY) BECAUSE PROD (EVEN RESIDUE) MAY (ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:IGNITE EXPLOSIVELY. HEAT PROT PROC:CNTNRS EXPOSED TO
    INTENSE HEAT FROM FIRES SHOULD BE COOLED W/WATER TO (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 6:PREVENT VAPOR PRESSURE BUILDUP WHICH COULD RESULT IN
    CONTAINER RUPTURE.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC:AND POLLUTION CONTROL AGENCIES. CALL SPILL
    RESPONSE TEAMS IF SPILL IS LARGE.
RTECS #:9999999ZZ

Ingred Name:OTHER PRECS:USE. USE ONLY W/ADEQ VENT. THIS PROD CNTNS
    PIGMENTS WHICH MAY BECOME DUST NUISANCE WHEN REMOVED BY (ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:ABRASIVE BLASTING, SANDING OR GRINDING.
RTECS #:9999999ZZ

Ingred Name:RESP PROT:COMBINATION OF PARTICULATE & GAS & VAP. IN
    CONFINED AREAS, USE (NIOSH/MSHA APPRVD) AIR LINE TYPE RESPS(ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:OR HOODS. RESP PROT MAY ALSO BE NEC IN ANY LATER
    MANUFACTURING OPERATIONS IN WHICH THESE PRODS MAY (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:BECOME AIRBORNE IN THE FORM OF VAPOR OR DUST.
RTECS #:9999999ZZ

Ingred Name:VENT:RESP TO PVNT OVEREXP. PROVIDE GEN DILUTION/LOC EXHST
    VENT IN VOL & PATTERN TO KEEP TLV OF MOST HAZ INGS (ING 16)
RTECS #:9999999ZZ

Ingred Name:ING 15:BELOW ACCEPTABLE LIM, LEL IN FIRE & EXPLO HAZ DATA
    BELOW STATED LIM & TO REMOVE DECOMP PRODS DURING (ING 17)
RTECS #:9999999ZZ

Ingred Name:ING 16:WELDING OR FLAME CUTTING ON SURFACES COATED WITH
    THESE PRODUCTS.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:RPTS HAVE ASSOC RPTD & PRLNGD OCCUP
    OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS DMG. INTENTIONAL MISUSE BY
    DELIB CONC & INHAL CONTENTS MAY BE HARMFUL/FATAL. DO NOT BRTH
    VAPS/SPRAY MIST. WEAR APPROP, PROP ERLY FITTED RESP (NIOSH/MSHA
    APPRVD) DURING & AFTER APPLICATN UNLESS AIR MONITORING DEMONSTRATES
    VAP/(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:MIST LEVELS ARE BELOW APPLIC LIMS.
    FOLLOW RESP MANUFACTURER'S DIRECTIONS FOR RESPIRATOR USE. PRODS MAY
    CAUSE NOSE, THROAT & EYE IRRIT. SYMPS OF OVEREXP INCLUDE DIZZ,
    HDCH, INTOX W/EUPHORIA L EADING TO UNCON.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYE:FLUSH W/LUKE WARM WATER FOR @ LST 15 MIN. SEEK MD IMMED.
    SKIN:FLUSH W/COPIOUS AMTS OF LUKE WARM WATER. REMOVE CONTAM CLTHG
    PROMPTLY. IF IRRIT OCCURS, GET MED ATTN. INHAL:REMOVE TO FRESH AIR.
    RESTO RE BRTHG IF REQ. CONT MD IMMED. INGEST:RINSE MOUTH IMMED.
    GIVE 6-8 OZ OF LIQ (NEVER GIVE ANYTHING BY MOUTH TO AN UNCON
    PERSON). DO NOT INDUCE VOMIT UNLESS ADVISED BY MD. CONT MD IMMED.

=====================  Fire Fighting Measures  =====================

Flash Point:104F,40C
Lower Limits:0.9%
Upper Limits:7.0%
Extinguishing Media:THE NATIONAL FIRE PROTECTION ASSOCIATION CLASS B
    EXTINGUISHER IS DESIGNED TO EXTINGUISH NFPA CLASS IB FLAMM LIQ
    FIRES.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
    . WATER SPRAY MAY BE INEFTIVE. WATER MAY BE USED TO COOL CLSD
    CNTNRS TO PVNT PRESS BUILDUP & POSS (SUP DAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
    HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
    EXPOSED TO EXTREME HEAT. DO NOT APPLY TO HOT (ING 6)

==================  Accidental Release Measures  ==================

Spill Release Procedures:STOP &/OR CNTN DISCHARGE IF IT MAY BE DONE
    SAFELY. KEEP ALL SOURCES OF IGNIT AWAY. VENT AREA OF SPILL. USE
    NON-SPKING TOOLS FOR CLEANUP. COVER W/INERT MATL TO REDUCE FUMES.
    KEEP OUT OF DRAINS, SEWERS/ WATERWAYS. CONT FIRE AUTHS. NOTIFY LOC
    HLTH(ING 9)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:BASED ON PRESENCE OF COMPONENTS 1,2,3
    AVOID EYE CONT. DO NOT STORE >120F. GROUND CNTNRS WHEN POURING &
    LIM FREE-FALL TO FEW IN TO PVNT STATIC SPKS.
Other Precautions:AVOID SPONTANEOUS COMBUST OF CONTAM RAGS/OTHER EASILY
    IGNITABLE ORG MATLS BY IMMED IMMERSION IN WATER. EMPTIED CNTNRS MAY
    CNTN HAZ PROPERTIES. DO NOT CUT/PUNCTURE CNTNR. DO NOT WELD NEAR
    CNTNR. KEEP C NTNR TIGHTLY CLSD WHEN NOT IN (ING 10)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IN OUTDOOR/OPEN AREAS, USE (NIOSH/MSHA APPRVD)
    MECH FILTER RESP TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY
    DURING SPRAY APPLICATN. IN RESTRICTED VENT AREAS, USE (NIOSH/MSHA
    APPRVD) CHEM MECH FILT ERS DESIGNED TO REMOVE A (ING 12)
Ventilation:USE VENT AS REQ TO CTL VAP CONCS. AVOID PRLNGD/RPTD BRTHG
    OF VAPS. IF EXPOS EXCEEDS TLV, USE NIOSH/MSHA APPRVD (ING 15)
Protective Gloves:REQ FOR PRLNGD/RPTD CONT. WEAR (SUPDAT)
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
    SHOWER . AN APRON SHOULD BE WORN TO AVOID SKIN CONTACT.
Work Hygienic Practices:WASH HANDS THORO BEFORE EATING & USING
    WASHROOM. REMOVE CONTAM CLTHG IMMED & DO NOT WEAR UNTIL IT HAS BEEN
    (SUPP DATA)
Supplemental Safety and Health
MFR TRADE/PART NO:GLOSS HOUSE & TRIM PAINT. FIRE FIGHT PROC:AUTO
    IGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT. IF WATER IS USED, FOG
    NOZZS ARE PREF. PROT GLOVES:RESIST GLOVES SUCH AS NATURAL RUB,
    NEOPRENE , BUNA N/NITRILE. HYGIENE PRACT:PROPERLY LAUNDERED.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>416F,>213C
Vapor Pres:2.0 @ 68F
Vapor Density:HVR/AIR
Spec Gravity:1.51 
Evaporation Rate & Reference:SLOWER THAN BUAC
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:21.88

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID EXPOS TO SPKS, OPEN FLAME, HOT SURFS & ALL SOURCES OF HEAT &
    IGNIT.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY PRDCE HAZ FUMES WHEN HEATED TO
    DECOMP AS IN WELDING. FUMES MAY CNTN CARBON MONOXIDE & DIOXDE &
    OXIDES OF NITROGEN.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DO NOT FLUSH TO SEWER, WATERSHED OR WATERWAY.
    DISPOSE OF THESE PRODUCTS IN ACCORDANCE WITH APPLICABLE LOCAL,
    COUNTY, STATE AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.