AMERICAN CONCRETE SYSTEMS INC -- HUB VOC FORM OIL, (H601) -- 8030-00N074529
===================== Product Identification =====================
Product ID:HUB VOC FORM OIL, (H601)
MSDS Date:10/09/1991
FSC:8030
NIIN:00N074529
MSDS Number: CCRVF
=== Responsible Party ===
Company Name:AMERICAN CONCRETE SYSTEMS INC
Address:7966 ARJONS DR
City:SAN DIEGO
State:CA
ZIP:92126
Country:US
Info Phone Num:619-578-5270
Emergency Phone Num:619-578-5270
CAGE:ACSYS
=== Contractor Identification ===
Company Name:AMERICAN CONCRETE SYSTEMS INC
Address:5966 ARJONS DR
Box:City:SAN DIEGO
State:CA
ZIP:92126
Country:US
Phone:619-578-5270
CAGE:ACSYS
============= Composition/Information on Ingredients =============
Ingred Name:NON-HAZARDOUS INGREDIENTS
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:VOLATILE ORGANIC COMPOUNDS (EPA REFERENCE METHOD 24):
COATING & MATERIAL - 0.29 LBS/GAL (35 G/L).
RTECS #:9999999VO
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE CONT:CAN CAUSE SEVERE
IRRITATION, REDNESS, TEARING & BLURRED VISION. SKIN CONT:PROLONGED
OR REPEATED CONTACT CAN CAUSE MODERATE IRRITATION, DEFATTING &
DERMATITIS. SKIN ABSORPTION:ORGANIC SO LVENTS ARE EASILY ABSORBED;
DRYING, REDNESS OR DERMATITIS ARE SIGNS OF REPEATED OVEREXPOSURE TO
THEIR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DEFAT ACTION. INHAL:EXCESSIVE INHAL OF
VAPS CAN CAUSE NASAL & RESP IRRIT, WEAK, DIZZ, FATG, NAUS, HDCH &
POSS UNCON & EVEN ASPHY. ASPIR INTO LUNGS CAN CAUSE CHEM PNEUM
WHICH CAN BE FATAL. ING EST:CAN CAUSE GI IRRIT, NAUS, VOMIT &
DIARR. CHRONIC:PRLNG/RPTD EXPOS ABOVE TLV MAY RSLT IN PERM BRAIN &
NERV SYS DMG.
Medical Cond Aggravated by Exposure:NONE KNOWN.
======================= First Aid Measures =======================
First Aid:EYES:FLUSH IMMEDIATELY W/LARGE AMOUNTS OF WATER FOR AT LEAST
15 MINUTES. TAKE TO MD FOR MEDICAL ATTENTION. SKIN:CLEANSE
THOROUGHLY W/SOAP & WATER. REMOVE ALL CONTAMINATED CLOTHING.
INHAL:REMOVE TO FRE SH AIR. INGEST:DRINK 1 OR 2 GLASSES OF WATER TO
DILUTE. DO NOT INDUCE VOMITING. CONSULT MD OR POISON CONTROL CENTER
IMMEDIATELY. TREAT SYMPTOMATICALLY.
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER SPRAY, CARBON DIOXIDE, FOAM, DRY CHEMICALS.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
FIGHT AS VOLATILE FIRE. CLOSED CONTAINERS MAY EXPLODE IN EXTREME
HEAT - KEEP AWAY FROM AREAS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:AVOID APPLICATION IN AREAS OF PILOT
LIGHTS, SPKS/OTHER IGNIT SOURCES AS VAPS MAY ACCUM ON FLOOR &
IGNITE. KEEP CNTNRS CLSD TIGHTLY & STORE IN COOL PLACE(SUPDAT)
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. DIKE, CONTAIN
OR ABSORB W/INERT MATERIAL (I.E., SAND, VERMICULITE, ETC). TRANSFER
TO CONTAINERS FOR RECOVERY OR DISPOSAL. PREVENT RUNOFF INTO SEWERS,
STREAMS OR OTHER B ODIES OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE OR USE NEAR SOURCES OF
HIGH TEMPERATURES, NEAR FIRE OR OPEN FLAME OR OTHER IGNITION
SOURCES.
Other Precautions:DO NOT TAKE INTERNALLY. AVOID PROLONGED OR REPEATED
EXPOSURE TO LEVELS ABOVE TLV.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF TLV IS EXCEEDED USE NIOSH APPROVED ORGANIC
VAPOR & MIST PROTECTION, SUPPLIED AIR OR SELF CONTAINED BREATHING
APPARATUS.
Ventilation:USE ADEQUATE MECHANICAL (GENERAL &/OR LOCAL) VENTILATION TO
MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:RESISTANT GLOVES SUCH AS NITRILE RUBBER.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . WEAR IMPERVIOUS CLOTHING.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING RESTROOMS.
REMOVE & WASH CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
EXPLO HAZ:WHEN NOT IN USE. EYE PROT:& FULL LENGTH FACESHIELD .
================== Physical/Chemical Properties ==================
Vapor Density:HVR/AIR
Spec Gravity:0.9
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NONE
Appearance and Odor:TYPICAL FOR SOLVENT BASED COATING.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:DO NOT EXPOSE TO HIGH TEMPERATURES OR
SOURCES.
Hazardous Decomposition Products:MAY FORM TOXIC MATERIALS, CARBON
DIOXIDE, CARBON MONOXIDE, ETC.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF I/A/W ALL LOCAL, STATE OR FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.