PRODUCTS-RESEARCH-SERVICE INC -- EPOXY/CHEMTITE HARDENER HARDENERS EC-01400 -- 8010-00N042018
=====================  Product Identification  =====================

Product ID:EPOXY/CHEMTITE HARDENER HARDENERS EC-01400
MSDS Date:04/09/1992
FSC:8010
NIIN:00N042018
MSDS Number: CDMRF
=== Responsible Party ===
Company Name:PRODUCTS-RESEARCH-SERVICE INC
Address:1602 BELLE CHASSE HWY SOUTH
City:BELLE CHASSE
State:LA
ZIP:70037
Country:US
Info Phone Num:504-394-3538
Emergency Phone Num:504-394-3538
Preparer's Name:PFL
CAGE:PRRES
=== Contractor Identification ===
Company Name:PRODUCTS-RESEARCH-SERVICE INC
Address:9929 HWY 23
Box:City:BELLE CHASSE
State:LA
ZIP:70037
Country:US
Phone:504-394-3538
CAGE:PRRES

=============  Composition/Information on Ingredients  =============

Ingred Name:ING 24: OCCURS. ANY PROPOSED USE OF PROD IN ELEVATED-TEMP
    PROCESSES SHOULD BE EVAL TO ASSURE SAFE OPERATION CNDTNS."
RTECS #:9999999ZZ

Ingred Name:ING 10: EXTREMELY HIGH CONCS MAY CAUSE LUNG DMG. SOME PERS
    MAY DEVELOP ASTHMA; SOME MAY DEVELOP LONG-TERM (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11: HYPERREACTIVE AIRWAYS, ASTHMA & OTHER RESP INJURY
    AFTER EXPOS TO EXTREMELY LOW CONCS OF ETHYLENEAMINES. (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:OTHER RESP IRRITANTS MAY CAUSE RXN IN PERS WHOSE
    AIRWAYS ARE HYPERREACTIVE. MFR SUGGESTS PERS W/ASTHMA OR(ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:OTHER LONG-STANDING RESP CNDTNS BE PROT FROM POTNTL
    EXPOS TO ETHYLENEAMINES. EYES:SEV CONJ IRRIT, IRITIS,(ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14: CORNEAL INJURY WHICH COULD LEAD TO PERM VISION
    LOSS. RPTD EXPOS TO HIGH CONCS OF VAPS MAY CAUSE LIVER & (ING 16)
RTECS #:9999999ZZ

Ingred Name:ING 15: KIDNEY INJURY. FORMALDEHYDE: RPTD/PRLNGD CNTCT MAY
    CAUSE ALLERGIC SKIN RXN (IE, SENSIT) IN SOME PERSONS.
RTECS #:9999999ZZ

Ingred Name:FIRST AID:SPECIFIC ANTIDOTE. BASE TREATMENT ON CTL OF SYMPS
    & CLINICAL CNDTN. CNTNS IPA. IF VICTIM IS CHILD GIVE(ING 18)
RTECS #:9999999ZZ

Ingred Name:ING 17:NO MORE THAN 1 GLASS OF WATER & 15CC SYRUP OF
    IPECAC. IF SYMPS SUCH AS LOSS OF GAG REFLEX, CONVLS/UNCON (ING 19)
RTECS #:9999999ZZ

Ingred Name:ING 18: OCCUR BEFORE EMESIS, GASTRIC LAVAGE SHOULD BE
    CONSIDERED FOLLOWING INTUBATION W/CUFFED ENDOTRACHEAL TUBE.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC: SALVAGE TANK. TAKE UP REMAINING LIQ ON SAND,
    CLAY, EARTH, FLOOR ABSORB & SHOVEL INTO CNTNRS. PVNT (ING 21)
RTECS #:9999999ZZ

Ingred Name:ING 20: RUN-OFF TO SEWERS, STREAMS OR OTHER BODIES OF
    WATER. IF RUN-OFF OCCURS, NOTIFY PROPER AUTHS AS REQD OF SPILL.
RTECS #:9999999ZZ

Ingred Name:HNDLG/STOR PRECS:TEMPS DECR W/INCRG VAP VOL & VAP/AIR CNTCT
    TIME & ARE INFLUENCED BY PRESS CHGS. IGNIT MAY OCCUR(ING 23)
RTECS #:9999999ZZ

Ingred Name:ING 22: AT TYPICAL ELEVATED-TEMP PROCESS CNDTNS, ESP IN
    PROCESSES OPERATING UNDER VACUUM IF SUBJECTED TO SUDDEN (ING 24)
RTECS #:9999999ZZ

Ingred Name:ING 23:INGRESS OF AIR/OUTSIDE PROCESS EQUIP OPERATING UNDER
    ELEVATED PRESS IF SUDDEN ESCAPE OF VAPS/MISTS TO ATM(ING 25)
RTECS #:9999999ZZ

Ingred Name:FORMALDEHYDE (SARA 302/313) (CERCLA)
CAS:50-00-0
RTECS #:LP8925000
Fraction by Wt: 0.2%
OSHA PEL:N/K 
ACGIH TLV:0.3 PPM, C
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:DIETHYLENETRIAMINE; (ETHYLENEAMINE MIXTURE)
CAS:111-40-0
RTECS #:IE1225000
Fraction by Wt: 6.1%
OSHA PEL:1 PPM
ACGIH TLV:1 PPM, S

Ingred Name:BUTYL ALCOHOL (SARA 313) (CERCLA)
CAS:71-36-3
RTECS #:EO1400000
Fraction by Wt: 1.4%
OSHA PEL:100 PPM
ACGIH TLV:50 PPM, S, C
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:ISOPROPYL ALCOHOL (SARA 313)
CAS:67-63-0
RTECS #:NT8050000
Fraction by Wt: 19%
OSHA PEL:400 PPM
ACGIH TLV:400 PPM; 500 STEL

Ingred Name:XYLENE; (AROMATIC HYDROCARBON) (SARA 313) (CERCLA)
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 22%
OSHA PEL:100 PPM
ACGIH TLV:100 PPM; 150 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:SUPDAT: EXPOSE SUCH CNTNRS TO HEAT, FLAME, SPKS, STATIC
    ELEC OR OTHER IGNIT SOURCES; MAY EXPLODE & CAUSE INJURY/DEATH.
RTECS #:9999999ZZ

Ingred Name:HAZ DECOMP PRODS: ETHYLENEDIAMINE, OTHER VOLATILE AMINES
    AND AMMONIA.
RTECS #:9999999ZZ

Ingred Name:EXPLAN OF CARCIN: TO BE CARCINOGEN. OSHA REGS: CFR 29
    1910.1048.
RTECS #:9999999ZZ

Ingred Name:EFTS OF OVEREXP: COMA. SKIN:PRLNGD/WIDESPREAD EXPOS MAY
    RSLT IN SENSIT & ALLERGIC SKIN RXN. INHAL:VAPS IRRIT & (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:MAY CAUSE EXCESS TEAR FORM, BURN SENSATION OF NOSE &
    THROAT, COUGH, WHEEZ, SHORTNESS OF BRTH, NAUS, VOMIT.(ING 11)
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:EYE:IRRITANT. STINGING, TEARING,
    REDNESS & SWELL. SKIN:MOD IRRIT, DEFAT, DERM. INHAL:NASAL & RESP
    IRRIT, CNS EFTS INCL DIZZ, WEAK, FATG, NAUSEA, HDCH & POSS UNCON.
    INGEST: GI IRRIT, NAUS, VOMIT & DIAR R. N-BUTANOL ALCOHOL:EVID THAT
    LONG-TERM RPTD EXPOS TO VAP CONCS >50PPM MAY RSLT IN HEARING LOSS.
    VAPS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:FORMALDEHYDE:IARC MONOGRAPHS, SUPP, VOL
    7, PG 211, 1987:GROUP 2A. NTP 7TH ANNUAL RPT ON CARCINS, 1991:
    ANTIC (ING 8)
Effects of Overexposure:HLTH HAZ:CAN CAUSE SPECIFIC INJURY TO CORNEA;
    LIQ ESP TOX IF ASPIR. XYLENE: PRLNGD/RPTD EXPOS TO HIGH CONCS MAY
    CAUSE NEURAL DYSFUNC. ASPIR INTO LUNGS CAN CAUSE POSS FATAL CHEM
    PNEUM EDEMA. ETHYLENEAM INES: INGEST:MOD TOX; THROAT & MOUTH BURNS,
    ABDOM PAIN, NAUS, VOMIT, DIARR, DIZZ, WEAK, THIRST, COLLAPSE & POSS
    (ING 9)
Medical Cond Aggravated by Exposure:LUNG DISORDERS, DERMATITIS, ASTHMA
    AND INFLAMMATORY OR FIBROTIC PULMONARY DISEASE.

=======================  First Aid Measures  =======================

First Aid:INHAL: REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE O*2/ARTF
    RESP) . INGEST:DO NOT INDUCE VOMIT. SKIN:THOROUGHLY WASH EXPOS AREA
    W/SOAP & WATER. REMOVE CONTAMD CLTHG; LAUNDER BEFORE REUSE.
    EYES:FLUS H W/LG AMTS OF WATER FOR AT LST 15 MIN,LIFTING UPPER &
    LOWER LIDS OCCASNLY. GET MED ATTN. BUTANOL IS ESP TOX IF ASPIR.
    VAPS APPEAR TO CAUSE SPEC VACUOLAR KERATOPATHY IN HUMANS. THERE IS
    NO (ING 17)

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:54.0F,12.2C
Lower Limits:1.0%
Upper Limits:12.0%
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE, ALCOHOL FOAM,
    WATER FOG.
Fire Fighting Procedures:NIOSH APPRVD SCBA & FULL PROT EQUIP. USE WATER
    SPRAY TO COOL FIRE EXPOS SURFS & PROT PERS. SHUT OFF "FUEL" TO
    FIRE. IF LEAK/SPILL HAS NOT IGNITED,(SUPDAT)
Unusual Fire/Explosion Hazard:VAP IS HVR/AIR & CAN TRAVEL CONSIDERABLE
    DIST TO IGNIT SOURCE & FLASH BACK. STATIC DISCHARGE, MATL CAN ACCUM
    STATIC CHARGES; CAN CAUSE INCENDIARY ELEC (SUPDAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:SM SPILL:ABSORB LIQ ON PAPER, VERMICULITE,
    FLOOR ABSORB/OTHER ABSORB MATL & TRANSFER TO HOOD. LG SPILL:ELIM
    ALL IGNIT SOURCES. EXCLUDE FROM AREA PERS NOT WEARING PROT EQUIP.
    STOP SPILL AT SOURCE. DIKE	AREA OF SPILL TO PVNT SPREAD, PUMP
    LIQ(ING 20)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:"WARNING:HOT ORG CHEM VAP/MISTS ARE
    SUSCEPTIBLE TO SUDDEN SPONT COMBUST WHEN MIXED W/AIR. IGNIT MAY
    OCCUR @ TEMPS BELOW THOSE PUBLISHED. IGNIT(ING 22)
Other Precautions:STORE IN COOL, DRY AREA W/VENT SUITABLE FOR STORING
    LISTED MATLS. CNTNRS, EVEN EMPTIED, WILL RETAIN PROD RESIDUE &
    VAPS. ALWAYS OBEY HAZ WARNINS & HNDL EMPTY CNTNRS AS IF FULL.
    PROVIDE NIOSH APPRVD RE SP PROT AGAINST FUMES FROM BURNING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF WORKPLACE EXPOS LIM(S) OF PROD/ANY COMPONENT
    IS EXCEEDED, NIOSH APPRVD AIR SUPPLIED RESP IS ADVISED. OSHA REGS
    ALSO PERMIT OTHER NIOSH APPRVD RESPS UNDER SPECIFIED CNDTNS.
    ENGINEERING OR ADMIN CTLS  SHOULD BE IMPLEMENTED TO REDUCE EXPOS.
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL &/OR LOCAL EXHAUST)
    VENTILATION TO MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . TO
    PVNT RPTD/PRLNGD SKIN CONTACT WEAR IMPERVIOUS CLTHG & BOOTS.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR SMOKING. SMOKE IN
    DESIGNATED AREAS ONLY.
Supplemental Safety and Health
FIRE FIGHT PROC:USE WATER SPRAY TO DISPERSE VAPS. EXPLO HAZ:DISCHARGE.
    GROUND &/OR BOND ALL 5 GAL PAILS & LARGER METAL CNTNRS INCL TANK
    CARS & TANK TRUCKS WHEN MATL IS TRANSFERRED. "EMPTY" CNTNRS RETA IN
    PROD RESIDUE & CAN BE DANGEROUS. DO NOT PRESSURIZE, CUT, WELD,
    BRAZE, SOLDER, DRILL OR GRIND CNTNRS. DO NOT (ING 6)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>137F,>58C
Vapor Density:HVR/AIR
Spec Gravity:0.911 
Evaporation Rate & Reference:SLOWER THAN BUTYL ACETATE
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR LIQUID; AROMATIC ODOR.
Percent Volatiles by Volume:47.5

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS, ACIDS, EPOXIDES, OXIDIZING
    AGENTS, ALDEHYDES, KETONES, ACRYLATES & ORG HALIDES.
Stability Condition to Avoid:HEAT, SPARKS, FLAME.
Hazardous Decomposition Products:STRONG MINERAL ACIDS. MAY FORM TOX
    MATLS:CO*2 & CO, VARIOUS HYDROCARBS, ETC. CO, CO*2 & OXIDES OF
    NITROGEN: (ING 7)

====================  Disposal Considerations  ====================

Waste Disposal Methods:SM SPILL:ALLOW VOLAT PART TO EVAP IN HOOD; ALLOW
    ENOUGH TIME FOR VAPS TO COMPLETELY CLEAR HOOD DUCT WORK. DISP OF
    REMAINDER I/A/W LOC, STATE & FED REGS. LG SPILL:DESTROY BY LIQ
    INCIN. DEPOSIT CONTAMD  ABSORB IN LANDFILL I/A/W FED, STATE & LOC
    REGS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.