MAGNOLIA PLASTICS INC -- 6345 MAGNOBOND EPOXY RESINS -- 8040-00F054589
===================== Product Identification =====================
Product ID:6345 MAGNOBOND EPOXY RESINS
MSDS Date:08/05/1997
FSC:8040
NIIN:00F054589
Kit Part:Y
MSDS Number: CGHKV
=== Responsible Party ===
Company Name:MAGNOLIA PLASTICS INC
Address:5547 PEACHTREE INDUSTRIAL BLVD
City:CHAMBLEE
State:GA
ZIP:30341-2234
Country:US
Info Phone Num:770-451-2777/800-457-4280
Emergency Phone Num:800-457-4280/770-451-2777
CAGE:22121
=== Contractor Identification ===
Company Name:MAGNOLIA PLASTICS INC
Address:5547 PEACHTREE INDUSTRIAL BLVD
Box:City:CHAMBLEE
State:GA
ZIP:30341-2234
Country:US
Phone:(770) 451-2777/(800) 457-4280
CAGE:22121
============= Composition/Information on Ingredients =============
Ingred Name:EPOXY RESIN
Fraction by Wt: 75-85%
Ingred Name:1-CHLORO-2,3-EPOXYPROPANE, EPICHLOROHYDRIN (SUSP ANIMAL
CARC BY IARC - GROUP 2A; SUSP CARC BY NTP) *97-3*
CAS:106-89-8
RTECS #:TX4900000
Fraction by Wt: <3%
Other REC Limits:5 PPM (SKIN)
OSHA PEL:5 PPM (SKIN)
ACGIH TLV:2 PPM (SKIN)
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:TITANIUM DIOXIDE, TITANIUM OXIDE (SUSPECTED ANIMAL
CARCINOGEN, IARC GROUP 3) *98-1*
CAS:13463-67-7
RTECS #:XR2275000
Fraction by Wt: <5%
OSHA PEL:15 MG/CUM
ACGIH TLV:10 MG/CUM (DUST)
===================== Hazards Identification =====================
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYES: MODERATELY IRRITATING.
POSSIBLE SKIN SENSITIZER. INGESTION: LOW TOXICITY.
Explanation of Carcinogenicity:SEE INGREDIENTS.
Effects of Overexposure:IRRITATION
Medical Cond Aggravated by Exposure:PRE-EXISTING SKIN & EYE DISORDERS.
======================= First Aid Measures =======================
First Aid:SKIN: WASH W/SOAP & WATER. EYES: FLUSH W/WATER FOR 15 MINS.
INHALATION: REMOVE TO FRESH AIR. GIVE OXGYEN IF NECESSARY.
INGESTION: DON'T INDUCE VOMITING. GIVE LARGE DOSES OF WATER. OBTAIN
MEDICAL ATTEN TION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:>200F
Extinguishing Media:WATER SPRAY, FOAM, CO2, DRY CHEMICAL
Fire Fighting Procedures:AVOID BREATHING SMOKE. IN CONFINED AREA: USE
NIOSH APPROVED SCBA. COOL FIRE EXPOSED CONTAINERS W/WATER.
Unusual Fire/Explosion Hazard:NONE
================== Accidental Release Measures ==================
Spill Release Procedures:AVOID CONTACT W/LIQUIDS & VAPORS. WIPE W/A
CLOTH/COLLECT ANY ABSORBENT MATERIAL. LARGE: DIKE & CONTAIN.
PUMP/SHOVEL INTO SALVAGE VESSELS.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL, DRY AREA IN TIGHTLY
CLOSED CONTAINERS. USE W/ADEQUATE VENTILATION. FOR INDUSTRIAL USE
ONLY.
Other Precautions:AVOID CONTACT W/SKIN & EYES. MAY CAUSE SEVERE EYE
BURNS. CORROSIVE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:FOR EXCESSIVE VAPORS/TO MAINTAIN BELOW TLV
LIMIT, NIOSH APPROVED RESPIRATOR IN COMPLIANCE TO 29-CFR 1910.134.
Ventilation:LOCAL EXHAUST/MECHANICAL EXHAUST
Protective Gloves:IMPERVIOUS RUBBER
Eye Protection:SPLASH PROOF CHEMICAL GOGGLES
Other Protective Equipment:IMPERVIOUS CLOTHING & BOOTS TO MINIMIZE
PERSONAL CONTACT. EYE WASH STATION, SAFETY SHOWER.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHNG BEFORE
REUSE. USE GOOD HYGIENE PRACTICES.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>225F
Vapor Pres:0
Vapor Density:>1
Spec Gravity:0.6
Evaporation Rate & Reference:(BUAC=1): <1
Solubility in Water:<0.1
Appearance and Odor:PINK PASTE
Percent Volatiles by Volume:0
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS & BASES
Stability Condition to Avoid:ELEVATED TEMPS.
Hazardous Decomposition Products:OXIDES OF CARBON & NITROGEN
Conditions to Avoid Polymerization:LARGE MIXTURES IN BULK. CURING
PROCESS IS EXOTHERMIC.
==================== Disposal Considerations ====================
Waste Disposal Methods:CURE, THEN BURY/INCINERATE. REMOVE SALVAGE
VESSELS TO A WASTE DISPOSAL SITE IAW/LOCAL, STATE & FEDERAL
REGULATIONS. CORROSIVE LIQUID UN3267.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.