DRYVIT SYSTEMS INC             -- SANDBLAST DPR FINISH                         
=======================================================
MSDS Safety Information 
=======================================================
FSC: 8030
MSDS Date: 04/01/1993
MSDS Num: BXXHZ
LIIN: 00N061326
Product ID: SANDBLAST DPR FINISH
MFN: 01
Responsible Party
Cage: 1U624
Name: DRYVIT SYSTEMS INC
Address: 1 ENERGY WAY
City: WEST WARWICK RI 02893-5561
Info Phone Number: 401-822-4100
Emergency Phone Number: 401-822-4100
Published: Y
=======================================================
Contractor Summary 
=======================================================
Cage: 1U624
Name: DRYVIT SYSTEMS INC
Address: 1 ENERGY WAY
City: WEST WARWICK RI 02893-5561
Phone: 401-822-4100
=======================================================
Ingredients 
=======================================================
Cas: 14808-60-7
RTECS #: VV7330000
Name: SILICA, CRYSTALLINE - QUARTZ; (SAND (ENCAPSULATED))
% Wt: 63-67
OSHA PEL: 15 MG/M3 (MFR)
ACGIH TLV: 0.1 MG/M3 RDUST
------------------------------
Cas: 7732-18-5
RTECS #: ZC0110000
Name: WATER
% Wt: 12-15
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Name: ACRYLIC LATEX BINDER; (ACRYLIC LATEX POLYMER/BINDER). %:8.5-10.2.
% Wt: <10.2
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Cas: 13463-67-7
RTECS #: XR2275000
Name: TITANIUM OXIDE; (TITANIUM DIOXIDE (RUTILE))
% Wt: 1-5.5
OSHA PEL: 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
=======================================================
Health Hazards Data 
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: NO
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: YES
IARC: YES
OSHA: NO
Effects of Exposure: IRRITATING & ABRASIVE IF SPLASHED INTO EYE BECAUSE OF
  SAND CONTENT; MAY BE A SKIN IRRITANT TO SENSITIVE INDIVIDUALS. NO ACUTE OR
  CHRONIC HAZARDS ARE KNOWN FOR MATERIAL AS PACKAGED AT POINT OF MANUFACT URE.
Explanation Of Carcinogenicity: SILICA, CRYSTALLINE-QUARTZ:IARC MONOGRAPHS,
  SUPP, VOL 7, PG 341, 1987:GRP 2A. NTP 7TH ANNUAL REPORT ON CARCINS, (SUPDAT)
Signs And Symptions Of Overexposure: NONE ESTABLISHED. NON-SPECIFIC IRRITATION
  IS POSSIBLE IN SENSITIVE INDIVIDUALS.
Medical Cond Aggravated By Exposure: NO KNOWN MEDICAL CONDITIONS AGGRAVATED BY
  EXPOSURE.
First Aid: TREAT FOR SYMPTOMS. IF IRRITATION OF EYES, NOSE OR THROAT OCCURS,
  MOVE TO FRESH AIR. INGEST:CALL MD IMMEDIATELY (FP N). INHAL:REMOVE TO FRESH
  AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP) (FP N). SKIN:F LUSH W/COPIOUS
  AMOUNTS OF WATER. CALL MD (FP N). EYES:WASH IMMEDIATELY W/LARGE AMOUNTS OF
  WATER FOR AT LEAST 15 MINUTES, LIFTING EYE LIDS OCCASIONALLY. GET MEDICAL
  ATTENTION.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SHOVEL & RECOVER, THEN DISPOSE OF AS COMMON
  WASTE. DO NOT FLUSH TO SEWER OR STREAMS; MATERIAL CAN CLOG DRAINS & MAKE
  STREAMS TURBID.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
  REGULATIONS (FP N). NON-REGULATED MATERIAL.
Handling And Storage Precautions: KEEP FROM FREEZING.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information 
=======================================================
Extinguishing Media: USE EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
  EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: CLOSED PLASTIC CONTAINERS MAY BUILD UP PRESSURE,
  RUPTURE OR MELT DUE TO EXTREME HEAT EXPOSURE.
=======================================================
Control Measures 
=======================================================
Respiratory Protection: NOT REQUIRED FOR WET MIXTURE USED EXTERIOR OR IN A WELL
  VENTILATED AREAS. NIOSH/MSHA APPROVED MECHANICAL FILTER RESPIRATOR SHOULD BE
  USED TO REMOVE SOLID AIRBORNE PARTICLES DURING SPRAY, SAWING & SAND ING
  OPERATIONS.
Ventilation: NONE REQUIRED WHEN USED EXTERIOR. PROVIDE ADEQUATE AIR MOVEMENT
  & MECHANICAL VENTILATION IF USED IN AN ENCLOSED AREA.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
  DESIGN CRITERIA (FP N). LONG SLEEVES, APRON AS NEEDED.
Work Hygienic Practices: OBSERVE RULES FOR GOOD PERSONAL HYGIENE & WORK
  PRACTICES. WASH HANDS BEFORE SMOKING, EATING OR USING TOILET FACILITIES.
Supplemental Safety and Health: EXPLAN OF CARCIN:1994:ANTICIPATED TO BE A LUNG
  CARCINOGEN (FP N).
=======================================================
Physical/Chemical Properties 
=======================================================
Spec Gravity: 1.75-1.9
Appearance and Odor: OPAQUE, SEMI-SOLID, WET STUCCO-LIKE MATERIAL; SLIGHT
  AMMONIA ODOR.
=======================================================
Reactivity Data 
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: NOT COMPATIBLE W/STRONG OXIDIZING AGENTS OR STRONG ACIDS.
Hazardous Decomposition Products: CO, CO*2, CN, NO*X.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information 
=======================================================
=======================================================
Ecological Information 
=======================================================
=======================================================
MSDS Transport Information 
=======================================================
=======================================================
Regulatory Information 
=======================================================
=======================================================
Other Information 
=======================================================
=======================================================
HAZCOM Label 
=======================================================
Product ID: SANDBLAST DPR FINISH
Cage: 1U624
Company Name: DRYVIT SYSTEMS INC
Street: 1 ENERGY WAY
City: WEST WARWICK RI
Zipcode: 02893-5561
Health Emergency Phone: 401-822-4100
Label Required IND: Y
Date Of Label Review: 07/06/1995
Status Code: C
Label Date: 07/06/1995
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE:IRRITATING & ABRASIVE IF SPLASHED INTO EYE
  BECAUSE OF SAND CONTENT; MAY BE A SKIN IRRITANT TO SENSITIVE INDIVIDUALS.
  CHRONIC:CANCER HAZARD! CONTAINS CRYSTALLINE SILICA-QUARTZ, WHICH IS LISTED AS
   AN ANIMAL LUNG CARCINOGEN (FP N).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
  information is formulated for use by elements of the Department of Defense.
  The United States of America in no manner whatsoever expressly or implied
  warrants, states, or intends said information to have any application, use or
  viability by or to any person or persons outside the Department of Defense
  nor any person or persons contracting with any instrumentality of the United
  States of America and disclaims all liability for such use. Any person
  utilizing this instruction who is not a military or civilian employee of the
  United States of America should seek competent professional advice to verify
  and assume responsibility for the suitability of this information to their
  particular situation regardless of similarity to a corresponding Department
  of Defense or other government situation.